DOD-STD-35-117(MI)
16 June 1978
CHAR
CODE STANDARD
PARAGRAPH
TESTING SHALL BE PERFORMED IN
1426 VIBRATION, RANDOM.
ACCORDANCE WITH THE BASE DOCUMENT, EXCEPT 1426.
TESTING SHALL BE PERFORMED IN
1427 VIBRATION, RANDOM.
ACCORDANCE WITH METHOD 214 OF MIL-STD-202.
1428 TEST CONDITION NUMBER AND LETTER 1428 SHALL APPLY.
1431 THE DURATION OF THE TEST SHALL BE 1431 HOUR(S).
1438 THE DURATION OF THE TEST SHALL BE 1438 MINUTE(S).
1452 THE MONITORING INSTRUMENTATION OF THE VIBRATION
EXCITATION SHALL BE ANY SUITABLE INSTRUMENTATION
SYSTEM.
1453 THE MONITORING INSTRUMENTATION OF THE VIBRATION
EXCITATION SHALL BE A CALIBRATED AC TO DC CONVERTER
AND STRIP CHART RECORDER.
1459 THE MONITORING INSTRUMENTATION OF THE VIBRATION
EXCITATION SHALL BE A CALIBRATED OSCILLOSCOPE.