DOD-STD-35-117(MI)
16 June 1978
CHAR
CODE STANDARD
PARAGRAPH
POLARIZING VOLTAGE SHALL BE 1395 VOLTS, DC.
1395
4980
LOADING VOLTAGE SHALL BE 4980 VOLTS, AC.
4981 LOADING VOLTAGE SHALL BE 4981 VOLTS, DC.
4991 4991 PERCENT OF THE SAMPLE SHALL BE SUBJECTED TO THE
POLARIZING VOLTAGE.
4985 STEP 7A OF METHOD 106 OF MIL-STD-202 IS NOT APPLICABLE.
STEP 7B OF METHOD 106 OF MIL-STD-202 IS NOT APPLICABLE-
4986
PERFORM DIELECTRIC WITHSTANDING VOLTAGE TEST AT HIGH
4983
HUMIDITY.
4984 PERFORM DIELECTRIC WITHSTANDING VOLTAGE TEST AFTER DRYING.
MOUNTING SHALL BE IN ACCORDANCE WITH 1449.
1449
THE REQUIREMENT(S) SHALL BE IN ACCORDANCE WITH
2292 OVERLOAD.
THE BASE DOCUMENT, EXCEPT 2292.
THERE SHALL BE NO MECHANICAL OR ELECTRICAL
2294 OVERLOAD.
FAILURE.